Strong Base Anion Resin
PA200 Detailed Introduction

Product Description

Pure PA200 is a Type I, macroporous strong-base anion exchange resin supplied in chloride or hydroxide and has high capacity, shock resistant with high physical stability.

Applications

Pure PA200 is widely used in multiple and mixed bed demineralizers, wherever complete ion and organic removal are required. It is also intended for use in all types of deionization systems, condensate polishing and chemical processing applications.

PA200

Typical Physical & Chemical Characteristics

Polymer Matrix Structure

Macroporous Polystyrene with DVB

Functional Group

R-N-(CH3)3+X

Ionic Form, as shipped

Chloride (Cl-)

Physical Form And Appearance

Spherical Beads

Sphericity

95% min.

Screen Size Range
--- U.S. Standard Screen

16-50 mesh, wet

Particle Size Range

+1.2 mm < 5%, -0.3 mm < 1%

Uniformity Coefficient

1.6 max.

Water Retention, Cl- form

50-60%

Swelling Cl- → OH-

20-30%

Shipping Weight, Cl- form

660-730 g/l (43 lbs/cu.ft, approx.)

Total Exchange Capacity, Cl- form

1.15 eq/l min.

pH Range

0-14

Suggested Operating Conditions

Maximum Temperature
Cl- form
OH- form

 

80ºC (170ºF) max.
60ºC (140ºF) max.

Minimum Bed Depth

0.6 m (24 inches)

Backwash Expansion

50-75% bed expansion

Regeneration
Regenerant Concentration
Flow Rate
Contact Time

 

4-6% NaOH
2 to 8 BV/h (0.25 to 1.00 gpm/cu.ft)
At least 60 Minutes

Displacement Rinse Rate

Same as Regenerant Flow Rate

Displacement Rinse Volume

10-15 gallons/cu.ft

Fast Rinse Rate

Same as Service Flow Rate

Fast Rinse Volume

35-60 gallons/cu.ft

Service Flow Rate

16-32 BV/h (2.0- 4.0 gpm/cu.ft)

Hydraulic Properties

 

 

Pressure Drop: The graph above shows the expected pressure loss per foot of bed depth as a function of flow rate at various temperatures.

Backwash: After each cycle the resin bed should be backwashed at a rate that expands the bed 50 to 75 percent. This will remove any foreign matter and reclassify the bed. The graph above shows the expansion characteristics of PA200.