Pure Resin Co., Ltd.

Pure Resin Co., Ltd.

Latest information at the first time!

Strong Base Anion Resin
PA510 Detailed Introduction

Product Description

Pure PA510 is a Type I, macroporous strong-base anion exchange resin with an acrylic matrix.

Applications

Pure PA510 is used in decolorisation from sugar production (especially cane sugar) and decolo--risation of organic products (glycerine, amino acid, tannin acid).

PA510

Typical Physical & Chemical Characteristics

Polymer Matrix Structure

Poly-acrylic Crosslinked with DVB

Functional Group

R-N-(CH3)3+X

Ionic Form, as shipped

Chloride (Cl-)

Physical Form And Appearance

Spherical Beads

Sphericity

95% min.

Screen Size Range
--- U.S. Standard Screen

16-50 mesh, wet

Particle Size Range

+1.2 mm < 5%, -0.3 mm < 1%

Uniformity Coefficient

1.6 max.

Water Retention, Cl- form

65-75%

Swelling Cl- → OH- 

25% max.

Shipping Weight, Cl- 

650-720 g/l (44 lbs/cu.ft, approx.)

Total Exchange Capacity, Cl- form

0.80 eq/l min.

pH Range

0-14

 

Suggested Operating Conditions

Maximum Temperature Cl- form

80ºC max.

Minimum Bed Depth

0.7 m

Backwash Expansion

50-75% bed expansion

Regeneration
Regenerant Concentration
Flow Rate
Contact Time

 

2-6% NaOH
2 to 8 BV/h (0.25 to 1.0 gpm/cu.ft)
At least 60 Minutes

Displacement Rinse Rate

Same as Regenerant Flow Rate

Displacement Rinse Volume

10-15 gallons/cu.ft

Fast Rinse Rate

Same as Service Flow Rate

Fast Rinse Volume

35-60 gallons/cu.ft

Service Flow Rate

5-10 BV/h

 

Operation Guide

Operation

Solution

Flow Rate(BV/h)

Dosage(BV)

Sugar Recovery

Clean Water

2.0~4.0

2.0~3.0

Back Wash

Clean Water

2.0~4.0

1.5~2.0

Regenerate

Mixed Liquor of
8~10%NaCl +
0.5~2%NaOH

1.5~2.0

2.5~3.5

Replacement

Pure Water

1.0~2.0

1.5~2.0

Rinse

Pure Water

10~15

4.0~6.0

Flushing

Original Liquor

2.0~4.0

30~60

 